Zia ul Mazhry, MD
Show Description +
Dr. Zia-ul-Mazhry, FRCS, presents his technique of scleral fixation for a posterior chamber IOL. He shares pearls of scleral fixation to avoid complications and ensure stable long term results.
Posted: 8/31/2012
Zia ul Mazhry, MD
Dr. Zia-ul-Mazhry, FRCS, presents his technique of scleral fixation for a posterior chamber IOL. He shares pearls of scleral fixation to avoid complications and ensure stable long term results.
Posted: 8/31/2012
Please log in to leave a comment.
Comments
Just Now
azee khan
12 years ago
need your contact number for discussion mine is 03448880086 telenor working in cmh hyderabad
Zia Mazhry
12 years ago
The IOL with holes on the optic available in my country is manufactured by ROTHO. However currently I am using hydrophobic single piece IOL by MBI, ALCON an ABBOT USA, and ZARACom Turkey. Recommended Overall diameter is 13.00 mm and optic is 6.00 mm. You can tie the suture easily at the point of maximum convexity.
Bhushan Khare
12 years ago
which IOL have you selected for the SF IOL ..it has holes on the haptic for fixation. Very few companies manufacture these now . Do you prefer such PMMA nonfoldable IOLs or you use foldable 3 piece IOLs as well in such cases
Fahad Aldohim
12 years ago
I cannot hear your voice, the sound of the music you used is high.