Optic Capture to Re-Center a Tilted IOL

Show Description +

Howard Gimbel, MD, shows a case where membrane optic capture solved a problem of significant lens tilt, induced astigmatism, and higher order aberration. The original cataract surgery was performed 8-year previously and the lens had one haptic in the bag and one in the vitreous.

Posted: 2/27/2015

Optic Capture to Re-Center a Tilted IOL

Howard Gimbel, MD, shows a case where membrane optic capture solved a problem of significant lens tilt, induced astigmatism, and higher order aberration. The original cataract surgery was performed 8-year previously and the lens had one haptic in the bag and one in the vitreous.