Tobias H. Neuhann, MD
Show Description +
Together with innovative devices like the Neuhann chopper from Geuder, as well as the new adaptive fluidics system from Bausch + Lomb, manual cataract surgery becomes quite simple in routine cases with advanced new EDOF IOLs.
Posted: 11/25/2019
Tobias H. Neuhann, MD
Together with innovative devices like the Neuhann chopper from Geuder, as well as the new adaptive fluidics system from Bausch + Lomb, manual cataract surgery becomes quite simple in routine cases with advanced new EDOF IOLs.
Posted: 11/25/2019
Please log in to leave a comment.
Comments
Just Now
Tobias Neuhann
5 years ago
Due to the fact that this capsular bag was huge we often see in the post follow-up stress folds in the posterior capsule. The fold is generated between the endpoints of the two haptics. These folds will produce glare at night and the only therapy is than, if the patient is complaining, YAG capsulotomy. And I hate complaining patients. With the help of the CTR these folds of the posterior capsule can be avoided as well as an early YAG capsulotomy. Simple, fast, reliable.
M Reffat,Msc, EBO
5 years ago
why CTR is used here? .. is there any subtle zonullar dialysis!!