IOL Exchange Technique

Show Description +

Frederico F. Marques, MD, PhD, and Daniela M.V. Marques, MD, PhD, present the case of 64-year-old female who underwent IOL exchange due to residual refractive error (-6.75 sph) and low readings of pachymetry (410um). An intraocular folding technique was performed after fracturing the superior haptic due to extensive adhesions and a 3-piece hydrophobic acrylic IOL was implanted uneventfully.

Posted: 12/05/2012

IOL Exchange Technique

Frederico F. Marques, MD, PhD, and Daniela M.V. Marques, MD, PhD, present the case of 64-year-old female who underwent IOL exchange due to residual refractive error (-6.75 sph) and low readings of pachymetry (410um). An intraocular folding technique was performed after fracturing the superior haptic due to extensive adhesions and a 3-piece hydrophobic acrylic IOL was implanted uneventfully.

Posted: 12/05/2012

Please log in to leave a comment.

More in Cataract

Complex Exchange

Ashraf Armia, MD

Laser-Assisted Repositioning

Vladimir Pfeifer, MD

Save the Bag

Eitan Livny, MD

Floaters

Daria Melnykova, MD; S.G. Saksonov, MD; A.S. Teslenko, MD; and A.V. Korobova, MD