Ertugrul Cuneyt Isik MD, Rabia Sakarya MD, Ugur Unsal MD, Yasar Sakarya MD
Show Description +
Yasar Sakarya, MD, Ugur Unsal, MD, Rabia Sakarya, MD, and Ertugrul Cuneyt Isik, MD, present four cases of IOL implantation without the use of an ophthalmic viscosurgical device. An irrigation cannula fixates the globe and inflates the bag during IOL insertion.
Posted: 1/11/2010
Ertugrul Cuneyt Isik MD, Rabia Sakarya MD, Ugur Unsal MD, Yasar Sakarya MD
Yasar Sakarya, MD, Ugur Unsal, MD, Rabia Sakarya, MD, and Ertugrul Cuneyt Isik, MD, present four cases of IOL implantation without the use of an ophthalmic viscosurgical device. An irrigation cannula fixates the globe and inflates the bag during IOL insertion.
Posted: 1/11/2010
Please log in to leave a comment.
Comments
Just Now
Muhammad Amer
15 years ago
Excellent.
yasar sakarya
15 years ago
The IOL injector I used was Duckworth& Kent (DK7797-2)that enables one hand injecting. It is important that you should occlude the tip of cartridge with IOL to prevent anterior chamber shallowing. IOL can be implanted directly into bag. If you bent trailing haptic on to IOL while inseting the IOL into cartridge, trailing haptic will also goes into anterior chamber. In this way you can avoid trailing haptic in the incision.
hasan koyu
15 years ago
excellent is a one word
marcos gomez
15 years ago
We have tried your technique with excellent results, we neither use OVD to put hidrophilic lenses in the cartridge and this reduces the chance of residual OVD. Care should be taken to fully introduce the trailing haptic in the anterior chamber and don´t let it out of the eye because this may cause chamber shallowing. Thanks for sharing.
Carlos Avila
15 years ago
Which kind of inyector you need to use? because with alcon´s you can´t do that, you need both hands to inject the lens
mustafa taseli
15 years ago
very good technic , tebrikler
yasar sakarya
15 years ago
Yes I use OVD to lubricate the cartridge. It si important that when placing the tip of haptic, you should occlude the lumen of cartridge with IOL. That is, Place the tip just before the IOL leaves the cartridge to prevent anterior chamber shallowing.
Mario Zambrano
15 years ago
I really like this technique!, excellent surgery...
ari weitzner
15 years ago
makes sense. blumenthal in israel was a big advocate of this. asc's will love it- saves money!