Gary Hirshfield MD
Show Description +
Ten days following implantation, Dr. Hirshfield demonstrates the removal of an Akreos lens (Bausch & Lomb, Rochester, NY) in an IOL exchange case. A pair of Mackool IOL Cutters (MSI Precision Instruments, Phoenixville, PA) are used to cut the lens 90% through the optic, so that the implant can be explanted in one maneuver.
Posted: 9/23/2009
Gary Hirshfield MD
Ten days following implantation, Dr. Hirshfield demonstrates the removal of an Akreos lens (Bausch & Lomb, Rochester, NY) in an IOL exchange case. A pair of Mackool IOL Cutters (MSI Precision Instruments, Phoenixville, PA) are used to cut the lens 90% through the optic, so that the implant can be explanted in one maneuver.
Posted: 9/23/2009
Please log in to leave a comment.
Comments
Just Now
Jon Blake
12 years ago
still need to understand the relationship between hydrophylic and calcification
Joel Thomas Muirhead
15 years ago
Very nice. Does this new hydrophilic material fuse to the capsule any quicker than say the typical hydrophobic acrylic material typically used here in the United States?