XtraFocus Pinhole Implant for Irregular Cornea and Fixated 3-Piece IOL

Show Description +

Lukan Mishev, MD, shares the case of a young patient one year after ammunition explosion trauma. PPV and extraction of IOFBs was performed. Initial suturing of the corneal wounds led to highly irregular cornea. Corneal sutures were removed 6 months after the initial surgery and healing was observed for 3 more months. A 3-piece Alcon MA60 IOL was sclerally fixated with the Yamane technique and a Morcher Xtrafocus Pinhole IOL was implanted in sulcus in order to eliminate the corneal irregularities.

Posted: 6/11/2018

XtraFocus Pinhole Implant for Irregular Cornea and Fixated 3-Piece IOL

Lukan Mishev, MD, shares the case of a young patient one year after ammunition explosion trauma. PPV and extraction of IOFBs was performed. Initial suturing of the corneal wounds led to highly irregular cornea. Corneal sutures were removed 6 months after the initial surgery and healing was observed for 3 more months. A 3-piece Alcon MA60 IOL was sclerally fixated with the Yamane technique and a Morcher Xtrafocus Pinhole IOL was implanted in sulcus in order to eliminate the corneal irregularities.

Posted: 6/11/2018

Please log in to leave a comment.

Comments

Lukan Mishev

7 years ago

Im right handed and it was more convenient for me to approach the trailing haptic first.

Lautaro Vera

7 years ago

Is there any particular reason to do the Yamane technique with the trailing Haptic first?