Eric D. Rosenberg, DO
Show Description +
Dr. Rosenberg presents a routine cataract surgery case in which a posterior capsular rupture occurred as a result of the I/A probe grabbing the capsular bag, which had somehow moved forward.
Posted: 6/22/2021
Eric D. Rosenberg, DO
Dr. Rosenberg presents a routine cataract surgery case in which a posterior capsular rupture occurred as a result of the I/A probe grabbing the capsular bag, which had somehow moved forward.
Posted: 6/22/2021
Please log in to leave a comment.
Comments
Just Now
mahmoud radwan
4 years ago
It Looks like the PCR occurred during the insertion of the implant