Posterior Capsular Rupture

Show Description +

Dr. Rosenberg presents a routine cataract surgery case in which a posterior capsular rupture occurred as a result of the I/A probe grabbing the capsular bag, which had somehow moved forward.

Posted: 6/22/2021

Posterior Capsular Rupture

Dr. Rosenberg presents a routine cataract surgery case in which a posterior capsular rupture occurred as a result of the I/A probe grabbing the capsular bag, which had somehow moved forward.

Posted: 6/22/2021

Please log in to leave a comment.

Comments

mahmoud radwan

5 years ago

It Looks like the PCR occurred during the insertion of the implant