David Chang MD
Show Description +
David Chang, MD, presents an urgent lens removal on an 18-year old high myope with chronic angle closure, uncontrolled pressure, and a flat chamber. Iris retractors support the capsulorhexis and create tension in this microspherophakic patient. Then a CTR and a modified Cionni CTR are placed into the capsular bag.
Posted: 3/30/2010
David Chang MD
David Chang, MD, presents an urgent lens removal on an 18-year old high myope with chronic angle closure, uncontrolled pressure, and a flat chamber. Iris retractors support the capsulorhexis and create tension in this microspherophakic patient. Then a CTR and a modified Cionni CTR are placed into the capsular bag.
Posted: 3/30/2010
Please log in to leave a comment.
Comments
Just Now
shri kant
15 years ago
Congatulations, for the wonderful surgical treatise.May be after such a nice placement of Cionni's ring endocapsular placement of IOLwould have been a better option.
David Chang
15 years ago
Scleral suturing of a PC IOL would be an alternative if the capsule had been torn/lost. The CTR reinforced capsular bag has enough zonular support for a PC IOL placed in the sulcus. The reason for the Cionni ring fixation is because the entire bag-complex wanted to tilt forward, and I was afraid that it would prolapse through the pupil, or might tip into the back of the iris. Remember, the crystalline lens was prolapsing into the AC.
lilach aharon
15 years ago
????? ??????, ?? ?? ?? ???.
Juan Rotundo
15 years ago
Congratulations. Scleral sutured IOL wouldn`t have been an alternative? If the answer is no, why? Thanks
ali alrajhi
15 years ago
I have a total of 20 eyes with microspherophakia all of them were done with 10-12 mm CTR without scleral suturing except in one where the zonules were to weak to accept insertion of CTR. Some had follow up to 9 years. Data was presented at AAO last year. In many of these cases CTR 10-12 (or even smaller that can be custom made)are adequate without Cionni type insertion. This year will presented as a video at the AAO if it is accepted.
LADAN ESPANDAR
15 years ago
Why did you put 2 CTR in the bag? Was it better to put just Cioni ring in the bag?
David Chang
15 years ago
Good question. The zonules were so lax that the capsular bag was not expanded except for the capsule retractors. One challenge with CTRs in these cases is that process of insertion will decenter the bag enough to shear loose the few remaining zonules. Therefore, I placed a std CTR while I still had the supporting hooks in place to expand the bag open. Without this, I would not have been able to get the Cionni ring in as atraumatically. With the external eyelet, it is difficult to insert the Cionni ring with capsular retractors in place. The IOL dioptric power was quite normal, as she had a normal axial length, despite a preop spectacle correction of -18 D.
mustafa taseli
15 years ago
congragulations, what are the diopries of IOLs?
ari weitzner
15 years ago
whew! chang rules.
View More