Opaque IOL Dropped to Retina

  Channels: Cataract Surgery | Posted 9/15/2015

A patient is undergoes for IOL exchange after the silicone oil caused IOL opacification. The capsular bag was stabilized with capsular bag hooks and the haptic is cut because the double c-loop haptic was adherent to the capsule. While the main incision was enlarged, the IOL fell down into the vitreous. A cornea trephine is filled with OVD to create an improvised plano concave lens for retina visualization.

Cataract • Cataract Surgery • Dislocated IOL, subluxed IOL • Intraocular lens, IOL, IOLs • IOL Exchange/IOL Explant • Ophthalmic viscosurgical device, OVD