Zonular Dialysis

Dr. David Chang presents a patient with a trampolining posterior capsule due to nasal zonular dialysis. As the cortex is grabbed with the I/A tip on the nasal side, wrinkling in the posterior capsule is visible. The bag is filled with a viscoelastic and a Henderson CTR is placed in the bag to hold the posterior capsule taut during cortical clean-up.

7,119 video views and 27,315 series views since

  • Bookmark

Comments (1)

What about trying Dewey's J-Cannula technique? Instead of pulling on the cortex.

eyeguy1 (24 months ago)