Posterior Polar Cataract with Capsule Rent

Dr. Garry Condon presents a posterior polar cataract case using a spatula to separate cortical material of from the lens capsule. Upon polishing of the posterior capsule with the I/A tip, the posterior capsule ruptures. OVD is used to tamponade the processes and stabilize the chamber. In between a viscoelastic sandwich, the capsular opening is converted to a posterior capsulorhexis with microforceps and a single piece acrylic lens is rotated in the bag.

4,607 video views and 26,919 series views since

  • Bookmark

Comments (1)

Great discussion, excellent cases. Thank you both for this virtual tour of your complex OR lives.

Dr. Lisa (24 months ago)